ICG PRODUCTS ARE UL, ULC, CSIRO AND BRANZ CERTIFIED
1 hour ASTM E119 Timber Floor Ceiling Assemblies. Timber framed walls exposed to fire from either or both sides (two-way FRR), and, or exposed to fire from the coated side (one-way FRR).
Exposed to Fire from below in Residential, Commercial or Industrial Building’s on the following substrates: 13mm Standard GIB Plasterboard, 6mm Fibre Cement Sheet, 12mm Plywood, Exposed Timber Floors/Ceilings (underside only).
NZBC C/VM2 Appendix A and can be used to prevent spread of fire on interior wall or ceiling substrates. It achieves Group 2-S on Type 1 (most reactive) as per C/VM2 A1.6, Table A2.
Can also be used to protect internal load-bearing wood from fire, therefore reducing cross sectional areas required as per NZS 3603:1993.
Closed cell or open cell SPF (Spray polyurethane foam). UL1715, 15 min rating achieved.
Product Category: Fire Protection Category
Product
Chemistry: ACRYLIC COPOLYMER LATEX
Volume Solids: 71.44 %
Specific Gravity: 1.37
VOC: 3 g/L
Density: 1442 g/L
Average Coating Pull-Off Strength: 400 psi
D2240-05(10)
Hardness test: 77
ASTM D2486 and D3450 Scrub Resistance: 172 Cycles
Percent Water Content: 28.46%
FBL-100 Load Bearing Horizontal Results
FBL-100 Pilot Scale Timber Framed Floor System Report
FBL-100 Pilot Scale Timber Framed Floor Ceiling system with Plywood Report
FBL-100 Pilot Scale Floor Ceiling system with cement sheet Report
FBL-100 Fire Rating Floor and Wall Assessment
FBL-100 Cone Test Report
FBL-100 ISO 9705 fire test Report
Directions For Use
• Steel Type: Select a Column type that you are using from the dropdown
• Number Of feet: Type in how may feet you have. (Please convert Metres to feet first using the conversion tool below)
• Hour Rating: Select the required rating from the dropdown